✨ New: Try our AI‑powered Search (Ctrl + K) — Read more

Storage and Preflight Readiness Guide

Prev Next

This guide gives deployment engineers a single preflight checklist that catches storage, latency, and disk-capacity issues before installation — the class of issues that most often surface later as false 'network' failures.

Getting Started

You will need:

  • Target host(s) meeting the deployment profile for your chosen installation platform. See On-Premise Deployment Options to select your installation platform and network mode.
  • Root or sudo shell access on each target host (Embedded Cluster) or a Kubernetes administrator context (KOTS).
  • The install package from get.pca.cisco.com staged locally.
  • Supported OS versions and profile boundaries listed in the Compatibility Matrix.

Installation Platform and Network Mode

Crosswork Assurance supports two installation platforms and two network modes. Your choice affects which preflight checks apply.

Installation Platform

Platform Description Kubernetes Expertise Setup Complexity
Embedded Cluster Provisions a lightweight K0s distribution on customer-supplied VMs. Self-contained with integrated management. Basic Low
Customer-Supplied Kubernetes (KOTS) Integrates with an existing Kubernetes platform (OpenShift, Rancher, etc.) through a web-based admin console. Advanced Medium

For a full comparison, see the Deployment Considerations Matrix in On-Premise Deployment Options.

Network Mode

Mode Description
Online Internet connectivity available. The installer retrieves container images and deployment artifacts from the Cisco registry.
Air-Gap No internet connectivity required during installation or operation. Offline license management and manual update procedures.

Compute and Memory

CPU, memory, and disk requirements vary by deployment profile. The table below summarizes the minimum resource floor per profile.

Profile CPU Cores Memory Disk Min Nodes Sessions Read IOPS Write IOPS
Lab 32 64 GB 750 GB 1 Up to 100 10,000 1,000
Small 72 128 GB 2.5 TB 1 Up to 10,000 10,000 1,000

Verify that your host meets or exceeds the profile floor before proceeding. For the full requirements table, see:

Multi-node deployments: The resources above represent the total required across all nodes. The minimum node size is 32 vCPU and 64 GB of RAM.

Hyper-threading and oversubscription: The requirements assume hyper-threading is enabled. Avoid hypervisor oversubscription; if needed, do not exceed a 4:1 vCPU-to-physical ratio and 20% RAM over-commit.

Storage Requirements

VM Storage Sizing (Embedded Cluster)

The following table details mount point sizes for Kubernetes hosting VMs.

Mount Point Lab Small
/boot 1 GB 1 GB
/ (root) 30 GB 40 GB
/opt 60 GB 108 GB
/var/log 10 GB 15 GB
/var/lib 649 GB ~2.28 TB
Total ~750 GB ~2.5 TB

Kubernetes Storage (KOTS)

The cluster must have an existing StorageClass available. Crosswork Assurance creates the required stateful components using the default StorageClass in the cluster.

Verify your default StorageClass:

kubectl get storageclass

The default class is marked (default) in the output. If no default exists, set one before installing.

IOPS Requirements

All profiles require a minimum of 10,000 read IOPS and 1,000 write IOPS. Verify your storage backend meets these thresholds before proceeding.

Disk Latency Gate (etcd P99 ≤ 10 ms)

etcd requires low write latency. If the disk backing etcd cannot sustain P99 ≤ 10 ms, the cluster will exhibit control-plane instability that often resembles a network problem.

Measure disk latency before installing. If the test fails, remediate storage before proceeding. See Troubleshoot On-Prem Installation Failures for failure signatures caused by slow disk.

Preflight Verification

Run the following checks in order. All must pass before you start the install.

Automated preflight

The installer also runs its own automated preflight checks after you begin deployment. Those checks read cluster-scoped information (Nodes, Namespaces, StorageClasses, installed APIs) and verify minimum requirements. However, a successful automated preflight is a point-in-time validation and does not replace your infrastructure approval, storage-performance validation, or security review. Run the manual checks below first to catch issues the automated checks do not cover.

All Deployments

Check Command Expected
OS version cat /etc/os-release Matches Compatibility Matrix
DNS resolver cat /etc/resolv.conf At least one nameserver entry (required even in air-gap)
Disk free (root) df -h / ≥ 30 GB (Lab) or ≥ 40 GB (Small)
Disk free (/opt) df -h /opt ≥ 60 GB (Lab) or ≥ 108 GB (Small)
Disk free (/var/log) df -h /var/log ≥ 10 GB (Lab) or ≥ 15 GB (Small)
Disk free (/var/lib) df -h /var/lib ≥ 649 GB (Lab) or ≥ ~2.28 TB (Small)
Disk IOPS see Disk Latency Gate ≥ 10,000 read / ≥ 1,000 write
etcd disk latency see Disk Latency Gate P99 ≤ 10 ms
Time sync chronyc tracking or timedatectl status Synchronized

KOTS Deployments (Additional)

Check Command Expected
Default StorageClass kubectl get storageclass One class marked (default)
socat installed which socat Prints path (for example, /usr/bin/socat)
Kubernetes version kubectl version --short Compatible with KOTS release (Replicated matrix)

Online Deployments (Additional)

Verify network reachability to the required external URLs:

URL Purpose
proxy-registry.pca.cisco.com Cisco container registry
update.pca.cisco.com Update service
replicated.app KOTS application
kots.io KOTS CLI
*.docker.io / *.docker.com Container images
cdn.auth0.com Authentication
charts.jetstack.io cert-manager
operator.min.io MinIO operator
prometheus-community.github.io Prometheus

Quick reachability test (repeat for each URL):

curl -s -o /dev/null -w "%{http_code}" https://proxy-registry.pca.cisco.com

A 200, 301, or 403 response confirms connectivity. A timeout or connection-refused indicates a firewall or proxy issue.

IPv6 Deployments (Additional)

If you deploy using an IPv6 address for the host machine, you must use a deployer version post-fixed with the label dual-stack. The preflight checks will fail if a non-dual-stack deployer version is used on an IPv6 host.

Symptom Decoder

Some symptoms look like network errors but are actually disk or latency issues.

When install or first-run fails with what appears to be a network error, check storage first:

Symptom Likely Root Cause Related Documentation
etcd leader elections repeat Disk P99 > 10 ms Troubleshoot On-Prem Installation Failures
Pod evictions / OOM at install Memory or disk pressure Installation on Kubernetes
Install hang Disk, latency, or resource starvation Troubleshoot On-Prem Installation Failures
unable to do port forwarding: socat not found socat package missing on node Installation on Kubernetes — Port Forwarding
Preflight fails on IPv6 host Deployer version is not dual-stack Installation on Kubernetes — Pre-Flight Checks

© 2026 Cisco and/or its affiliates. All rights reserved.

For more information about trademarks, please visit:
Cisco trademarks 
For more information about legal terms, please visit: