--- title: "Set Dry-Contact Inputs" slug: "setting-dry-contact-inputs-lx" tags: ["alarm", "Assurance Sensors", "Assurance Sensor LX-S"] updated: 2026-07-07T13:34:44Z published: 2024-01-23T15:42:56Z canonical: "docs.crossworkassurance.cisco.com/setting-dry-contact-inputs-lx" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.crossworkassurance.cisco.com/llms.txt > Use this file to discover all available pages before exploring further. # Set Dry-Contact Inputs Units with the dry-contact hardware option enabled are equipped with four dry-contact inputs that enable you to monitor and report the status of external devices. The reporting of the current state of each dry-contact input is found in **System ▶ Alarm ▶Dry-Contact**. **Cable Pinout for Dry-Contact Inputs** ![Skylight element LX v7.9_-22.bmp](https://cdn.document360.io/01d1de5e-a375-4fbc-aa82-666ac04c2113/Images/Documentation/Skylight%20element%20LX%20v7.9_-22%281%29.bmp?sv=2026-02-06&spr=https&st=2026-11-16T06%3A10%3A31Z&se=2026-11-16T07%3A10%3A31Z&sr=b&sp=r&sig=ioqIqxqdil%2Fs21iDFa%2BVwuoGr0fsosCYHJA0%2F1dUeMM%3D) | Pin | Signal | | --- | --- | | 1 | GND1 (ground) | | 2 | DC1 (dry-contact 1 input) | | 3 | GND3 (ground) | | 4 | DC2 (dry-contact 2 input) | | 5 | GND2 (ground) | | 6 | DC3 (dry-contact 3 input) | | 7 | GND4 (ground) | | 8 | DC4 (dry-contact 4 input) | **To set dry-contact inputs** 1. Access the page **System ▶Configuration ▶Dry-Contact**. 2. Select **Enable** for each dry-contact input you wish to monitor. 3. Enter values for each of the parameters, then click **Apply**. For more information on specific parameters, refer to the following table. **Dry-Contact Input Parameters (System ▶Configuration ▶Dry-Contact)** | Parameter | Description | | --- | --- | | Enable | Enable/Disable the use of the dry-contact input. When enabled, the alarm point for this input is created and the input is monitored. | | Normal Input State | Select the normal state of the input. An alarm will be raised when the input state of the dry-contact is different from the normal state for more than three consecutive samples. Possible values are: - Closed - Open | | Input Sampling Period | The time, expressed in milliseconds, between two consecutive readings of the input state. Range: 100–1000 milliseconds, expressed in steps of 100 milliseconds. | | Name | The name to assign to the dry-contact input. Range: *1–127* characters; numbers and special characters are supported. | **© 2026 Cisco and/or its affiliates. All rights reserved.** For more information about trademarks, please visit: [Cisco trademarks](https://www.cisco.com/c/en/us/about/legal/trademarks.html)[](https://www.cisco.com/c/en/us/about/legal/trademarks.html) For more information about legal terms, please visit: [Cisco legal terms](https://www.cisco.com/c/en/us/about/legal/terms-conditions.html)